Method of Use
DARACEM 19-CFMQ is supplied ready for use, and should be added to concrete mixes either during the mixing cycle or at the same time as the water, or alternatively it should be added in its supplied form to a normal concrete mix a few minutes before the pour is made.
In the latter case a mixing cycle of at least 2 minutes should be provided to ensure complete dispersion.
Compatibility with Cements
DARACEM 19-CFMQ is compatible with all Portland, Pozzolanic and Blast furnace cements.
It is also compatible with concrete containing fly ash and or silica fume.
Compatibility with other Admixtures
DARACEM 19-CFMQ should not be premixed under any circumstances with other admixtures. While some admixtures can be usefully combined within the same mix the performance of this product may well be affected by the presence of other chemicals and we recommend that GCP Applied Technologies be contacted for advice in all such circumstances.
Addition Rates
Range: 0.60%–2.0% volume by weight of cement The optimum dosage is assessed after preliminary trials depending upon the actual mix constituents and specifications required. Addition rates outside of the recommended dosage range may be used for special concrete applications. In such circumstances it is important to conduct preliminary trials on the actual mix constituents to assess the effect on the properties of the concrete at the dosage level specified.