CLARENA® CM150C

Clay Mitigating Solution for Concrete

Product Description

The CLARENA® CM150C family of products is a new class of materials specifically designed and formulated to meet the needs of the concrete producer.

Designed to selectively react with clay contaminants in both coarse and fine aggregates, this highly engineered, irreversible chemical reaction can eliminate the negative effects of clay-bearing sands and aggregates in concrete.

Advantages

  • Enables and enhances use of PCE-based admixtures
  • Increased slump and/or strength depending upon targeted objective
  • Enables use of lower-quality, currently marginal materials

Typical Properties

WRDA P4
Appearance Colourless to pale yellow liquid
Specific Gravity 1.15
pH 5 - 8
Freezing Point -3°C
Storage Temperature 30°C
Shelf Life 12 months

Benefits

Even a relatively trace presence of clay in a concrete mix can have a two-fold negative impact. Firstly, the mix will have a higher water demand due to the clay’s absorbency.

Normally, this increased water demand would be addressed through superplasticizing admixtures; however, the secondary negative impact of clay is its affinity for polycarboxylate (PCE) molecules, which diminishes the efficacy of PCE-based admixtures. CLARENA® CM150C reacts with the clay particles, eliminating the PCE affinity, and enabling PCE-based admixtures to work with increased efficiency.

Method Of Use

CLARENA® CM150C is designed to be used as received. Further dilution is not recommended unless exceptional circumstances exist at a given site. In most instances, CLARENA® CM150C products can be administered by pre-dosing onto clay-containing sand or aggregates, or by dosing directly into the mixer.

When CLARENA® CM150C is added at the concrete batching plant, it should be added at the beginning of the loading sequence so that it can come into contact with the aggregates and water before any admixture is introduced to the mix.

Please contact GCP Applied Technologies for further assistance in determining the best application and dosing sequence to meet your specific needs.

Dosing Equipment

CLARENA® CM150C should be proportioned through a calibrated dosing system suitable for the dosage and throughput at a given site.

Recommended equipment designs are available from GCP.

Addition Rates

The addition rate of CLARENA® CM150C is a direct function of the amount of clay contained within your specific concrete mix. GCP Applied Technologies can assist you in determining the appropriate dosage by testing your constituent materials to determine their clay content, and calculating the appropriate dosage.

Compatibility

Significant material and process variability can exist when producing concrete. The compatibility of CLARENA® CM150C products should be verified in all end-use applications prior to full-scale use.

Storage

CLARENA® CM150C should be stored in a shaded area not exposed to direct sunlight. Should area’s storage be exposed to freezing temperatures, provisions should be made for insulating and heating in order to prevent excess viscosity and to aid pump-ability.

Health and Safety

All precautions defined on the Safety Data Sheet (SDS) must be followed at all times.

Technical Service

Field Engineers from GCP are available to assist in laboratory and plant evaluations of CLARENA® CM150C. Please contact your local GCP representative for further assistance.

 

gcpat.uk | United Kingdom customer service: +44 (0) 1480 478421

We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate, and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations, and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right.

CLARENA is a trademark, which may be registered in the United States and/or other countries, of GCP Applied Technologies Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status.

© Copyright 2020 GCP Applied Technologies Inc. All rights reserved.

GCP Applied Technologies (UK) Ltd, Gate St, Dukinfield SK16 4RU.

This document is only current as of the last updated date stated below and is valid only for use in the United Kingdom. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.uk. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service.

Last Updated: 2023-06-13

https://gcpat.uk/en-gb/solutions/products/clarena-cm150c