ADVA® XT5

Workability enhancing admixture

Product Description

ADVA® XT5 is a revolutionary advancement in time activated polycarboxylate-based technology.

This patent pending, consistence (slump and flow) enhancing admixture, when used in conjunction with many water reducers (standard, mid-range, or high-range), will significantly increase the duration of slump or flow retention.

ADVA® XT5 is manufactured under closely controlled conditions and formulated for use as received. 

Advantages

  • Flexible degree of slump retention through adaptable dosing
  • Increases slump life with minimal impact on set times
  • Better control of operational costs by adjusting the slump life retention on an “as needed” basis during the initial dosage adjustment
  • Eliminates the need for re-tempering with water at the job site
  • Improves consistence at job sites resulting in ease of placement

Typical Properties

ADVA® XT5
Appearance Straw - Amber liquid
Specific Gravity (20°C) 1.064 - 1.084
Alkali Content (eq.Na20) ≤ 1.5
Chloride Content Nil

Uses

ADVA® XT5 is specifically intended for use where extended workability with minimal time of setting extension is desired without compromising plastic or hardened concrete properties. ADVA® XT5 produces concrete with consistent slump properties while providing the degree of consistence necessary to provide easy placement and consolidation. Conventional high-range water reducers may not provide sufficient slump life for applications with unpredictable or long transportation and placement times. As a result, concrete may be re-tempered with water at a job site to achieve desired workability. The addition of ADVA® XT5 used in conjunction with water reducers eliminates the need for re-tempering at job sites to achieve the desired consistence.

Addition Rates

Addition rates of ADVA® XT5 can vary with the type of application and the desired slump specifications, but will range from 130 to 650 mL/100 kg) of cement as an extended slump life admixture. In most instances, the addition of 260 to 390 mL/100 kg of cement will be sufficient. At higher dosage rates, some water may have to be removed from the mix to maintain plastic concrete cohesion. GCP strongly recommends pretrial testing the concrete with ADVA® XT5 before production use to optimise dosage rates due to concrete materials, ambient conditions and project requirements that change over time. Please consult your GCP Applied Technologies representative for more information and
assistance.

Compatibility with Other Admixtures and Batch Sequencing

ADVA® XT5 is compatible with most GCP admixtures as long as they are added separately to the concrete mix. In general, it is recommended that ADVA® XT5 be added to the concrete mix near the end of the batch sequence for optimum performance. Different sequencing may be used if local testing shows better performance. Pretesting of the concrete mix should be performed before use, as conditions and materials change in order to assure compatibility with other admixtures, and to optimise dosage rates, addition times in the batch sequencing and concrete performance. For concrete that requires air entrainment, the use of an air-entraining agent (such as DAREX® AE3 or DAREX® AE3P product lines) is recommended to provide suitable air void parameters for freeze-thaw resistance. Please consult your GCP Applied Technologies representative for guidance.

Packaging & Handling

ADVA® XT5 is available in bulk delivered by metered trucks, in totes and drums. ADVA® XT5 should be stored at temperatures above 0°C and below 50° for proper dispensing and use. It will begin to freeze at 0°C, but will return to full strength after thawing and thorough agitation.

Dispensing Equipment

It is preferable that It is preferable that ADVA® XT5 should be introduced into the mixer by means of automatic dispensing equipment.

Advice on dispensing can be obtained from GCP Applied Technologies.. should be introduced into the mixer by means of automatic dispensing equipment. Advice on dispensing can be obtained from GCP Applied Technologies.

Health and Safety

For further information on Health and Safety matters regarding this product we recommend that you consult the relevant Safety Data Sheet from GCP Applied Technologies.

In line with general chemical handling precautions avoid contact with skin or eyes and protective gloves/goggles should be worn. Technical Service Our Technical Service department of GCP Applied Technologies is available to assist you in the correct use of our performance chemicals.

 

gcpat.uk | United Kingdom customer service: +44 (0) 1480 478421

We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate, and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations, and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right.

ADVA is a trademark, which may be registered in the United States and/or other countries, of GCP Applied Technologies Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status.

© Copyright 2020 GCP Applied Technologies Inc. All rights reserved.

GCP Applied Technologies (UK) Ltd, Gate St, Dukinfield SK16 4RU.

This document is only current as of the last updated date stated below and is valid only for use in the United Kingdom. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.uk. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service.