GELACRYL™ AR

Poly-acrylate injection system with improved wet-dry characteristics using standard Gelacryl resins combined with a polymer blend reinforcing agent

Product Description

GELACRYL™ Acrylic Rubbers are 2-component poly-acrylate gels. The A-component is a poly-acrylate resin, the B-component is a polymer blend. The 2-components are injected with a 2-component 1:1 ratio piston pump. Once polymerised, GELACRYL™ Acrylic Rubbers form a resilient, highly elastomeric gel. Due to their exceptionally low viscosity and low surface tension, GELACRYL™ Acrylic Rubbers show better penetration into cracks than water

  • Resin = GELACRYL™/GELACRYL™ SR/GELACRYL™ Superflex
  • Polymer blend = GELACRYL™ AR2
  • Catalyst = TE 300
  • Initiator = SP 200
  • Decelerator = KF 500

Product Advantages

  • GELACRYL™ AR injection systems are injected with a twin piston, 1:1 ratio pump.
  • Exceptionally low viscosity. GELACRYL™ AR penetrates into cracks 0.1 mm wide.
  • Excellent post-expansion properties in contact with water.
  • GELACRYL™ AR does not need continuous contact with water.
  • Excellent adhesion to concrete when GELACRYL™ Superflex is used.
  • Very good chemical resistance to most acids, alkalis and biological attack (*).
  • Can be used in temperatures ranging from 5°C to 70°C.
  • Poly-acrylate resin, free of acryl-amides.

(*) For chemical resistances please contact your GCP representative.

Field of Application

GELACRYL™ Acrylic Rubbers are used in applications where fluctuating groundwater levels are encountered. The addition of the polymer blend in the B-component improves the wet-dry characteristics of the cured compound.

GELACRYL™/GELACRYL™ Superflex

  • Remedial repair of water leaks.
  • Preventative waterproofing of structures.
  • Water control during tunnelling operations.
  • Curtain grouting.
  • Waterproofing subterranean structures in concrete or masonry (cellars, underground car parks, etc.).
  • Waterproofing cracks in concrete or rock.
  • Waterproofing tunnel segments.
  • Waterproofing tunnel liners.
  • Dilatation joints with small dilatation (GELACRYL™ Superflex)

GELACRYL™ SR

  • Sewer joint repair (automated or manual).
  • Water control during tunnel operations.
  • Waterproofing of underground concrete or masonry structures

Application

Consult the Material Safety Data Sheet (MSDS) before mixing and/or handling.

  • GELACRYL™ Acrylic Rubbers are developed to be used below ground in applications with a fluctuating groundwater level.
  • Holes are drilled in the affected area.
  • Water can be forced into the hole to determine whether all cracks can be injected and if additional injection/pressure control holes need to be drilled.
  • Visible surface leaks and cracks should be sealed with a fast setting cement prior to injection. Allow the cement to harden completely before injecting GELACRYL™ Acrylic Rubbers.
  • Use standard packers or equipment according to local standards.
  • GELACRYL™ Acrylic Rubbers is then injected into the holes with a high pressure pump capable of reaching pressures up to 200 bars. This forces the GELACRYL™ Acrylic Rubber deep into the structures and allows penetration into the smallest cracks.
  • When surface leaks show up during pumping, stop immediately and seal the leak by approved method.

1. Composition

  • The injection grout needs to be prepared immediately before the injection.
  • Both components are pre-weighted, no further dilution of component 2 with water is required. Prior to injection only the additives need to be added to both components.
  • After preparation, the components are injected simultaneously in a ratio of 1:1.

2. Preparation

Component 1

  • Add the required quantity of TE 300 catalyst to the GELACRYL™ resin. GELACRYL™ resin and TE 300 need to be thoroughly mixed. In case of using GELACRYL™ SR, an additional amount of water needs to be added to Component 1.

Component 2

  • The tank is first filled with the same quantity of GELACRYL™ AR2. Then slowly and under continuous mixing to avoid lumps, add the required quantity of SP 200. Mix well at 600 rpm.
  • The components should only be prepared immediately before use of the grout. We do not recommend preparation in advance.
  • As soon as temperatures of the environment or material reach 20°C or higher, the resin and grout need to be regularly oxygenated by passing compressed air through the containers

 

3.Typical Formulations/Gel Times

GELACRYL™

T (°C) GELACRYL™ (l) TE 300 (l) GELACRYL™ AR2 (l) SP 200 (kg) SP 200 (bottles) Gel Time
5°C 42 1.60 42 1.58 3.5 1’
5°C 42 0.75 42 1.13 2.5 5’
5°C 42 0.67 42 0.45 1 10’
5°C 42 0.59 42 0.23 0.5 30’
10°C 42 1.35 42 1.13 2.5 1’
10°C 42 0.67 42 0.68 1.5 5’
10°C 42 0.59 42 0.45 1 10’
10°C 42 0.50 42 0.12 0.25 30’
20°C 42 1.18 42 1.13 2.5 1’
20°C 42 0.59 42 0.45 1 5’
20°C 42 0.50 42 0.23 0.5 10’
20°C 42 0.42 42 0.23 0.5 30’

GELACRYL™ SR

T (°C) GELACRYL™ SR (l) Water (I) TE 300 (l) GELACRYL™ AR2 (l) SP 200 (kg) SP 200 (bottles) Gel Time
5°C 21 18.5 1.95 42 1.80 4 1’
5°C 21 18.5 1.00 42 0.90 2 5’
5°C 21 18.5 0.80 42 0.68 1.5 10’
5°C 21 18.5 0.70 42 0.45 1 30’
10°C 21 18.5 1.80 42 1.13 2.5 1’
10°C 21 18.5 0.70 42 0.68 1.5 5’
10°C 21 18.5 0.60 42 0.45 1 10’
10°C 21 18.5 0.40 42 0.23 0.5 30’
20°C 21 18.5 1.30 42 1.13 2.5 1’
20°C 21 18.5 0.60 42 0.45 1 5’
20°C 21 18.5 0.40 42 0.45 1 10’

GELACRYL™ Superflex

T (°C) GELACRYL™ Superflex (l) TE 300 (l) GELACRYL™ AR2 (l) SP 200 (kg) SP 200 (bottles) Gel Time
5°C 42 1.60 42 1.58 3.5 1’
5°C 42 0.75 42 1.13 2.5 5’
5°C 42 0.67 42 0.45 1 10’
5°C 42 0.59 42 0.23 0.5 30’
10°C 42 1.43 42 1.13 2.5 1’
10°C 42 0.67 42 0.68 1.5 5’
10°C 42 0.59 42 0.45 1 10’
10°C 42 0.50 42 0.12 0.25 30’
20°C 42 1.18 42 1.13 2.5 1’
20°C 42 0.59 42 0.45 1 5’
20°C 42 0.50 42 0.23 0.5 10’

4. Injection

  • The injection work should be carried out with the DE NEEF® IP 2C-200-A twin piston, 1:1 ratio high pressure pump, suitably modified for use with the GELACRYL™ AR System.

Consumption

Has to be estimated by the engineering or operator and depends on width and depth of the cracks and voids to be filled.

Technical Data / Properties

Property   Value   Norm
GELACRYL™ Resins        
See respective technical data sheet for full technical data properties.    
GELACRYL™ AR2        
Density   ± 1kg / dm3   ASTM D-1638
Viscosity (@ 25°C)   < 40 mPas   ASTM D-1638
Solids   ±50 %   ASTM D-1010
Cured form Acrylic Rubber GELACRYL™  GELACRYL™ SR  GELACRYL™ Superflex   
Elongation at Break 80 % 20 % 200 % ASTM 638
Post-expansion in contact with water 70 % 55 % 160 % Test DNC

Appearance

After curing, product turns into a flexible rubber.

GELACRYL™ Resin: Green liquid
GELACRYL™ SR Resin: Transparent liquid
GELACRYL™ Superflex Resin: Blue liquid
GELACRYL™ AR2: White liquid
TE 300: Transparent liquid
SP 200: White salt
KF 500: Orange liquid

Packaging

GELACRYL™ Resins

25kg plastic jerry can 21L
1 pallet 24 jerry cans

GELACRYL™ AR2

21kg plastic jerry can 21L
1 pallet 24 jerry cans

TE 300

25kg plastic jerry can  
1 pallet 24 jerry cans

SP 200

0.45kg plastic bottle  
1 box 22 bottles
1 pallet 24 boxes

KF 500

25kg plastic jerry can  
1 pallet 24 jerry cans

Storage

GELACRYL™ resins, GELACRYL™ AR2, TE 300, SP 200 and KF 500 should be stored in a frost-free environment under cover, clear of the ground, in the original closed containers. The storage temperature must be below 35°C.

Shelf life: 1 year

Accessories

To be ordered separately

  • IP 2C-200-A airdriven twin piston pump.
  • Packers and connectors.

(Please consult the relevant Technical Data Sheet).

Health and Safety

GELACRYL™ resins are slightly irritating.

GELACRYL™ AR2 is not classified.

TE 300 is classified as irritant.

SP 200 is classified as harmful/oxidising.

Always wear appropriate protective gear: rubber gloves, safety goggles and boots.

Always avoid prolonged breathing of the grout vapours. Use a fresh air blower and flexible ducts in any confined or badly ventilated area.

In case of contact with the eyes, flush with water for 15 minutes. If swallowed, call a physician immediately.

For full information, consult the relevant Material Safety Data Sheet.

gcpat.uk | United Kingdom customer service: +44 (0) 1480 478421

We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate, and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations, and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right.

GELACRYL is a trademark, which may be registered in the United States and/or other countries, of GCP Applied Technologies, Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status.

© Copyright 2018 GCP Applied Technologies, Inc. All rights reserved.

This document is only current as of the last updated date stated below and is valid only for use in the United Kingdom. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.uk. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service.

Last Updated: 2023-06-13

https://gcpat.uk/en-gb/solutions/products/de-neef-waterproofing-injection-solutions/gelacryl-ar